Your channel viewers will see links here, including "subscribe" and "add as friend".
Profile
Name
Nick's Garage
Description
WELCOME!!!!! Our goal is to share inspiration regarding tinkering around in the garage.
Subscribers
676
Subscriptions
Friends (4)
Channel Comments
|
garyjacques3217
(5 years ago)
keep the camera still, I thought there must be an earthquake going on...I getting seasick
|
|
IronheadBonds
(3 years ago)
You should try stick welding in the rain. I think it would be right up your alley.
|
|
guerradan1958
(4 years ago)
This does help in understanding how to wire the motor. Thanks!
|
|
tatrofam350
(3 years ago)
Ty man you helped me out a lot t
|
|
mikehill5301
(4 years ago)
Yep cool exactly where I am with a new motor and need too wire it with a switch.
|
|
losmetalsindustrialrecords1592
(3 years ago)
Very informative
|
|
WPGinterceptor460Interceptor
(8 months ago (edited))
Browns are always Capacitor then BLACK is full speed, Red is slow speed! YOUR FURNACE ONLY USES 2 SPEEDS AT A TIME! the other 1-2-3 (depending on how many your motor has) speeds are parked unless you wire them for use.. pick the speed u want and wire it! white is common, green is ground! so lets say you want to run it only on full speed... you could connect the browns (capacitor) and then connect white for common, then black to black and it will run on full speed!... if you wanted to run on the slowest speed the only wire your changing out is the RED, so remove the back to black and connect the red to red and rest is same above but now it will run on slowest speed!! for your 2 speed furnace your going black to black and usually red to red... faster for Heating fan and slower speed for A/C!!!! YOUR CONTROL BOX WILL PICK BEWTEEN THE 2 SPEEDS DURING OPERATION! get it?? my furnace motor is a 4 speed and runs 2 speeds ONLY, black and red (fastest and slowest).. ive cut the other wires YELLOW AND BLUE as ill never need them = PARKED!!!! BLUE IS MEDIUM HIGH SPEED AND YELLOW IS MEDIUM LOW SPEED.... alot of people TIE UP the 2 parked speeds, I prefer to just cut them and tape off the end so no arching or issues
|
|
thetipjack7063
(4 years ago)
Love it!
|
|
joeyjuarez2257
(5 years ago)
LMAO this dude is awesome !! He laughed when it sparked! What also tripped me out was all the wires were exposed and he still powered that bad boy up!!
|
|
alchemy1
(4 years ago)
If you were to remove the two wires that go to the capacitor and hook them up to an ohmmeter, should the ohmmeter show continuity?
|
|
jalenjose3905
(4 years ago)
Wow I dont know the heck you saying but its very interesting
|
|
LilStewie
(5 years ago (edited))
Now hear me out. I have no certs in HVAC/Electrical.....but all my amateur wiring experience says this was one of the best super sketch vids lmao :-D. I know that laugh/chuckle well, its the "whew, ok, just a few sparks so guess we're still good, carrying on" laugh.
|
|
GOLDHAWK360
(5 years ago)
Lol I love the shocks man
|
|
innovativeoutdoorsman5067
(3 years ago)
But what are the 3 speeds? My motor says 1050 rpm but what are the other speeds?
|
|
jalenjose3905
(4 years ago)
So the white its always neutral or negative
|
Add comment